Sauna heater specs compared
The numbers your electrician needs, copied from each manufacturer’s installation manual or data sheet. 240 V single-phase models only.
| Brand | Model | kW | Amps @240 V | Breaker | Wire (per maker) | Room volume (ft³) | Controls | Source |
|---|---|---|---|---|---|---|---|---|
| Harvia | KIP-30-B1 / W1 | 3 | 12.5 | Not stated | #12/2 | 84–130 | Built-in (B1) or separate control (W1) | [1] |
| Harvia | KIP-45-B1 / W1 | 4.5 | 18.8 | 30 A[2] | #10/2 | 100–210 | Built-in (B1) or separate control (W1) | [1] |
| Harvia | KIP-60-B1 / W1 | 6 | 25 | 30 A[2] | #10/2 | 170–300 | Built-in (B1) or separate control (W1) | [1] |
| Harvia | KIP-80-B1 / W1 | 8 | 33.3 | 40 A[2] | #8/2 | 250–425 | Built-in (B1) or separate control (W1) | [1] |
| HUUM | DROP 4 | 4.5 | 18.75 | 30 A | 10 AWG (min.) | 106–248 | Separate HUUM controller | [3] |
| HUUM | DROP 6 | 6 | 25 | 30 A | 10 AWG (min.) | 177–318 | Separate HUUM controller | [3] |
| HUUM | DROP 7 | 7.5 | 31.25 | 40 A | 8 AWG (min.) | 248–389 | Separate HUUM controller | [3] |
| HUUM | DROP 9 | 9 | 37.5 | 50 A | 8 AWG (min.) | 283–460 | Separate HUUM controller | [3] |
Installation notes from the manuals
- Harvia: heater must be permanently installed (no plug) and wired by a licensed electrician; use copper wire rated 194°F (90°C) within sauna walls. [1]
- Harvia: connect to a standard 2-pole breaker; no GFI. Harvia says a GFI breaker may cause nuisance tripping and voids the warranty on internal components. [1]
- HUUM: only a certified electrician may connect the heater; the power cable must meet UL 62 (US) / CSA 49 (Canada); crimping the cable ends is mandatory; HUUM recommends connecting without a GFCI breaker. [3]
- HUUM: for each 1 ft² of uninsulated brick, tile, or glass wall, add 3.3 ft³ to the room volume before choosing a heater; the warranty is void if output doesn't match the calculated room volume. [3]
Reading the table
- Two heaters with the same kW draw the same current at the same voltage (6 kW ÷ 240 V = 25 A). They differ in rated room range, controls, and stone capacity.
- Harvia’s KIP manual lists wire size but not breaker size. Breaker sizes shown for KIP45/60/80 come from Harvia’s data sheets (dealer-hosted copy). KIP-30 is “not stated.”
- Room ranges assume a properly insulated sauna. Glass, tile, or stone surfaces push you toward a bigger heater; see the calculator.
Where to buy: Harvia · HUUM. Disclosure.
Sources
- Harvia KIP Owner's/Operator's Manual (PDF), Harvia (harviaheater.com) (accessed November 18, 2026) — Table 1 room sizes; 240 V wiring tables; 90°C copper wire within sauna walls; standard 2-pole breaker, no GFI.
- Harvia KIP data sheets (combined, 2026) (PDF, dealer-hosted copy), Harvia data sheet hosted by a dealer (accessed November 18, 2026) — Breaker sizes: KIP45 30 A, KIP60 30 A, KIP80 40 A.
- HUUM DROP 2.0 User Manual, US (PDF, H1001L08 v8), HUUM (accessed November 18, 2026) — Table 2 (240 V): output, room volume, amps, circuit breaker, minimum wire size.